Thermocouples Bare Wire R S B Type For Precision Temperature Measuring Instrument

MOQ: 5 Kg
Price: Negotiable
Standard Packaging: Thermocouple wire are rolled on ABS white spool and packed with plastic film,in cartoon boxes.
Special packaging requirements can also be accommodated.
OEM is also acceptable
Delivery Period: 5-21 days
Payment Method: L/C, T/T, Western Union, MoneyGram
Supply Capacity: 300 tons per month
Detail Information
Place of Origin
China
Brand Name
Victory
Certification
CE,ROHS,ISO 9001
Model Number
Type R S B
Product Name:
Thermocouple Bare Wire
Diameter:
0.1-8mm
Special Limits Of Error:
+/- 0.6C Or 0.1%
Negative:
Platinum
Grade:
IEC854-1/3
EMF Tolerance:
+/- 1.5C Or +/- .25%
Temperature Range:
-58 To 2700F (-50 To 1480C)
Certificate:
ISO9001
Color:
Bright
Application:
Cable & Wire
Highlight:

Platinum Rhodium Thermocouple Bare Wire

,

Thermocouple Bare Wire S Type

,

Bright type s thermocouple extension wire

Product Description

Introduction:


Platinum-rhodium alloy thermocouple bare wire is a commonly used thermocouple temperature measurement device, which is composed of alloy wires of platinum and rhodium. According to different alloy compositions and structures, they can be divided into B-type, R-type and S-type thermocouple bare wires.

The measurement principle of these platinum-rhodium alloy thermocouple bare wires is based on the thermoelectric effect, that is, temperature changes cause a small potential difference between the alloy wires. By measuring this potential difference, the temperature of the environment can be accurately calculated. They offer good corrosion resistance and low thermocouple resistance drift, making them suitable for applications requiring high accuracy and long-term stability.

 

Thermocouple wire type B:


Type B thermocouple bare wire uses platinum-rhodium alloy wire (platinum 70%, rhodium 30%) and platinum-rhodium alloy wire (platinum 94%, rhodium 6%) as thermocouple materials. It has a wide temperature measurement range (usually from 0 degrees Celsius to 1820 degrees Celsius), high accuracy and stability, and is suitable for various temperature monitoring and control application scenarios.

  • Temperature range: Suitable for high temperature measurements, typically measuring temperatures from 0°C to 1,820°C (32°F to 3,308°F).
  • Advantages: It has good linear characteristics and stability, and is suitable for temperature measurement in high temperature environments.
  • Specific parameters of interest: Thermoelectric potential output varies with temperature changes, typically at the microvolt (μV) level.
  • Specific application fields: Widely used in high temperature measurement and control fields such as glass industry and ceramic industry.

 

Thermocouple wire type R:


Type R thermocouple bare wire uses platinum-rhodium alloy wire (87% platinum, 13% rhodium) and pure platinum wire as thermocouple materials. It has a wide high temperature measurement range (usually from 0 degrees Celsius to 1768 degrees Celsius), high accuracy and reliability, and is suitable for industrial control and scientific research applications in high temperature environments.

  • Temperature range: Suitable for high temperature measurements, typically measuring temperatures from 0°C to 1,600°C (32°F to 2,912°F).
  • Advantages: It has excellent linear characteristics and stability and can provide high-precision temperature measurement results.
  • Specific parameters of interest: Thermoelectric potential output varies with temperature changes, typically at the microvolt (μV) level.
  • Specific application areas: Often used for temperature measurement and control in high-temperature processes such as steel smelting and aluminum plants.

 

Thermocouple wire type S:


S-type thermocouple bare wire also uses platinum-rhodium alloy wire (platinum 90%, rhodium 10%) and platinum-rhodium alloy wire (platinum 94%, rhodium 6%) as thermocouple materials. It has a wide temperature measurement range (usually from 0 degrees Celsius to 1768 degrees Celsius), high accuracy and reliability, and is suitable for industrial control and scientific research applications in various high temperature environments.

  • Temperature range: Suitable for a wide temperature range, typically measuring temperatures from 0°C to 1,600°C (32°F to 2,912°F).
  • Advantages: It has excellent linear characteristics and stability and is suitable for a wide range of temperature measurement needs.
  • Specific parameters of interest: Thermoelectric potential output varies with temperature changes, typically at the microvolt (μV) level.
  • Specific application fields: Widely used in temperature measurement and control in the oil and gas industry, furnace and heat treatment industry, and steel metallurgy.

 

Code
Wire Component of the thermocouple
+Positive leg
- Negative Leg
N
Ni-Cr-Si(NP)
Ni-Si-magnesium (NN)
K
Ni-Cr(KP)
Ni-Al(Si) (KN)
E
Ni-Cr(EP)
Cu-Ni (EN)
J
Iron (JP)
Cu-Ni (JN)
T
Copper (TP)
Cu-Ni (TN)
B
Platinum Rhodium-30%
Platinum Rhodium -6%
R
Platinum Rhodium-13%
Platinum
S
Platinum Rhodium -10%
Platinum
  • Standards:
  •  
ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

 

  • Working temperature:

 

Diameter/mm Type Long time Working Short period Working
temperature/°C temperature/°C
0.5 S 1300 1600
0.5 R 1300 1600
0.5 B 1600 1700

 

 

  • Chemical Composition:
  •  
Conductor Name Polarity Code Pt% Rh%
Pt90Rh Positive SP 90 10
Pt Negative SN,RN 100 --
Pt87Rh Positive RP 87 13
Pt70Rh Positive BP 70 30
Pt94Rh Negative BN 94 6

 

contact us

email:victory@dlx-alloy.com

Oem service:
Welcome customized size
We are experience factory for OEM&ODM service

 

Thermocouples Bare Wire R S B Type For Precision Temperature Measuring Instrument 0 Thermocouples Bare Wire R S B Type For Precision Temperature Measuring Instrument 1

 

Q&A:


Which temperature range is suitable for type B thermocouple bare wire?
A: Type B thermocouple bare wire is suitable for high temperature measurement ranges from 0°C to 1,820°C (32°F to 3,308°F).

What are the main advantages of type R thermocouple bare wire?
Answer: R-type thermocouple bare wire has excellent linear characteristics and stability and can provide high-precision temperature measurement results.

In what application areas are S-type thermocouple bare wires common?
Answer: S-type thermocouple bare wire is commonly used in temperature measurement and control in the oil and gas industry, furnace and heat treatment industry, and steel metallurgy.

products
PRODUCTS DETAILS
Thermocouples Bare Wire R S B Type For Precision Temperature Measuring Instrument
MOQ: 5 Kg
Price: Negotiable
Standard Packaging: Thermocouple wire are rolled on ABS white spool and packed with plastic film,in cartoon boxes.
Special packaging requirements can also be accommodated.
OEM is also acceptable
Delivery Period: 5-21 days
Payment Method: L/C, T/T, Western Union, MoneyGram
Supply Capacity: 300 tons per month
Detail Information
Place of Origin
China
Brand Name
Victory
Certification
CE,ROHS,ISO 9001
Model Number
Type R S B
Product Name:
Thermocouple Bare Wire
Diameter:
0.1-8mm
Special Limits Of Error:
+/- 0.6C Or 0.1%
Negative:
Platinum
Grade:
IEC854-1/3
EMF Tolerance:
+/- 1.5C Or +/- .25%
Temperature Range:
-58 To 2700F (-50 To 1480C)
Certificate:
ISO9001
Color:
Bright
Application:
Cable & Wire
Minimum Order Quantity:
5 Kg
Price:
Negotiable
Packaging Details:
Thermocouple wire are rolled on ABS white spool and packed with plastic film,in cartoon boxes.
Special packaging requirements can also be accommodated.
OEM is also acceptable
Delivery Time:
5-21 days
Payment Terms:
L/C, T/T, Western Union, MoneyGram
Supply Ability:
300 tons per month
Highlight

Platinum Rhodium Thermocouple Bare Wire

,

Thermocouple Bare Wire S Type

,

Bright type s thermocouple extension wire

Product Description

Introduction:


Platinum-rhodium alloy thermocouple bare wire is a commonly used thermocouple temperature measurement device, which is composed of alloy wires of platinum and rhodium. According to different alloy compositions and structures, they can be divided into B-type, R-type and S-type thermocouple bare wires.

The measurement principle of these platinum-rhodium alloy thermocouple bare wires is based on the thermoelectric effect, that is, temperature changes cause a small potential difference between the alloy wires. By measuring this potential difference, the temperature of the environment can be accurately calculated. They offer good corrosion resistance and low thermocouple resistance drift, making them suitable for applications requiring high accuracy and long-term stability.

 

Thermocouple wire type B:


Type B thermocouple bare wire uses platinum-rhodium alloy wire (platinum 70%, rhodium 30%) and platinum-rhodium alloy wire (platinum 94%, rhodium 6%) as thermocouple materials. It has a wide temperature measurement range (usually from 0 degrees Celsius to 1820 degrees Celsius), high accuracy and stability, and is suitable for various temperature monitoring and control application scenarios.

  • Temperature range: Suitable for high temperature measurements, typically measuring temperatures from 0°C to 1,820°C (32°F to 3,308°F).
  • Advantages: It has good linear characteristics and stability, and is suitable for temperature measurement in high temperature environments.
  • Specific parameters of interest: Thermoelectric potential output varies with temperature changes, typically at the microvolt (μV) level.
  • Specific application fields: Widely used in high temperature measurement and control fields such as glass industry and ceramic industry.

 

Thermocouple wire type R:


Type R thermocouple bare wire uses platinum-rhodium alloy wire (87% platinum, 13% rhodium) and pure platinum wire as thermocouple materials. It has a wide high temperature measurement range (usually from 0 degrees Celsius to 1768 degrees Celsius), high accuracy and reliability, and is suitable for industrial control and scientific research applications in high temperature environments.

  • Temperature range: Suitable for high temperature measurements, typically measuring temperatures from 0°C to 1,600°C (32°F to 2,912°F).
  • Advantages: It has excellent linear characteristics and stability and can provide high-precision temperature measurement results.
  • Specific parameters of interest: Thermoelectric potential output varies with temperature changes, typically at the microvolt (μV) level.
  • Specific application areas: Often used for temperature measurement and control in high-temperature processes such as steel smelting and aluminum plants.

 

Thermocouple wire type S:


S-type thermocouple bare wire also uses platinum-rhodium alloy wire (platinum 90%, rhodium 10%) and platinum-rhodium alloy wire (platinum 94%, rhodium 6%) as thermocouple materials. It has a wide temperature measurement range (usually from 0 degrees Celsius to 1768 degrees Celsius), high accuracy and reliability, and is suitable for industrial control and scientific research applications in various high temperature environments.

  • Temperature range: Suitable for a wide temperature range, typically measuring temperatures from 0°C to 1,600°C (32°F to 2,912°F).
  • Advantages: It has excellent linear characteristics and stability and is suitable for a wide range of temperature measurement needs.
  • Specific parameters of interest: Thermoelectric potential output varies with temperature changes, typically at the microvolt (μV) level.
  • Specific application fields: Widely used in temperature measurement and control in the oil and gas industry, furnace and heat treatment industry, and steel metallurgy.

 

Code
Wire Component of the thermocouple
+Positive leg
- Negative Leg
N
Ni-Cr-Si(NP)
Ni-Si-magnesium (NN)
K
Ni-Cr(KP)
Ni-Al(Si) (KN)
E
Ni-Cr(EP)
Cu-Ni (EN)
J
Iron (JP)
Cu-Ni (JN)
T
Copper (TP)
Cu-Ni (TN)
B
Platinum Rhodium-30%
Platinum Rhodium -6%
R
Platinum Rhodium-13%
Platinum
S
Platinum Rhodium -10%
Platinum
  • Standards:
  •  
ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

 

  • Working temperature:

 

Diameter/mm Type Long time Working Short period Working
temperature/°C temperature/°C
0.5 S 1300 1600
0.5 R 1300 1600
0.5 B 1600 1700

 

 

  • Chemical Composition:
  •  
Conductor Name Polarity Code Pt% Rh%
Pt90Rh Positive SP 90 10
Pt Negative SN,RN 100 --
Pt87Rh Positive RP 87 13
Pt70Rh Positive BP 70 30
Pt94Rh Negative BN 94 6

 

contact us

email:victory@dlx-alloy.com

Oem service:
Welcome customized size
We are experience factory for OEM&ODM service

 

Thermocouples Bare Wire R S B Type For Precision Temperature Measuring Instrument 0 Thermocouples Bare Wire R S B Type For Precision Temperature Measuring Instrument 1

 

Q&A:


Which temperature range is suitable for type B thermocouple bare wire?
A: Type B thermocouple bare wire is suitable for high temperature measurement ranges from 0°C to 1,820°C (32°F to 3,308°F).

What are the main advantages of type R thermocouple bare wire?
Answer: R-type thermocouple bare wire has excellent linear characteristics and stability and can provide high-precision temperature measurement results.

In what application areas are S-type thermocouple bare wires common?
Answer: S-type thermocouple bare wire is commonly used in temperature measurement and control in the oil and gas industry, furnace and heat treatment industry, and steel metallurgy.