logo
Send Message

Changzhou Victory Technology Co., Ltd victory@dlx-alloy.com 86-199-06119641

Changzhou Victory Technology Co., Ltd Company Profile
products
Home > products > Thermocouple Compensating Wire > Strand Or Solid K Type Thermocouple Extension Wire/Compensation Wire With PFA Insulated PFA Sheath

Strand Or Solid K Type Thermocouple Extension Wire/Compensation Wire With PFA Insulated PFA Sheath

Product Details

Place of Origin: China

Brand Name: Victory

Certification: CE,ROHS,ISO 9001

Model Number: K,N,E,J,T,B,R,S Types

Document: Product Brochure PDF

Payment & Shipping Terms

Minimum Order Quantity: 5

Packaging Details: Spool package with Carton box, Coil package with polybag

Delivery Time: 5-21 days

Payment Terms: L/C, T/T, Western Union, MoneyGram

Supply Ability: 300 tons per month

Get Best Price
Product Details
Highlight:

K Type Thermocouple Extension Wire

,

PFA Insulated Compensation Wire

Product Name:
Thermocouple Extension Wire
Color:
Bright
Certificate:
ISO9001
Temperature Range:
32 To 392F (0 To 200C)
EMF Tolerance:
+/- 2.2C Or +/- .75%
Grade:
Extension Grade NPX/NNX
Positive:
Ni-cr-si
Negative:
Ni-si-magnesium
Other Name:
Nicrosil
Special Limits Of Error:
+/- 1.1C Or 0.4%
Product Name:
Thermocouple Extension Wire
Color:
Bright
Certificate:
ISO9001
Temperature Range:
32 To 392F (0 To 200C)
EMF Tolerance:
+/- 2.2C Or +/- .75%
Grade:
Extension Grade NPX/NNX
Positive:
Ni-cr-si
Negative:
Ni-si-magnesium
Other Name:
Nicrosil
Special Limits Of Error:
+/- 1.1C Or 0.4%
Product Description

Thermocouple Extension Wire is widely used in multiple industries and applications. In industrial control systems, it can be used to monitor and control the temperature of kilns, furnaces, boilers and heating equipment. In chemical process engineering, it can be used to monitor the temperature of equipment such as reactors, distillation columns, and storage tanks. In a laboratory environment, it can be used in applications such as scientific research, testing and calibration.

Thermocouple Extension Wire has a wide operating temperature range to accommodate different temperature requirements. At the same time, it also has corrosion resistance, wear resistance and mechanical strength to meet various harsh working environments.

In summary, the Thermocouple Extension Wire is a reliable, stable and accurate cable that provides an important solution for temperature measurement and control. Whether in industrial production sites, laboratories or scientific research fields, it can provide accurate and reliable temperature transmission, helping users achieve precise temperature monitoring and control.

 

 


Thermocouple Wire

Code Wires component of the thermocouple
  +Positive leg -Negative leg
N Ni-cr-si (NP) Ni-si-magnesium (NN)
K Ni-Cr (KP) Ni-Al(Si) (KN)
E Ni-Cr (EP) Cu-Ni<constantan> (EN)
J Iron (JP) Cu-Ni<constantan> (JN)
T Copper (TP) Cu-Ni<constantan> (TN)

 

​Standards

ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

 

 

Thermocouple No. indexing Compensation wire type Usag Classification Measuring junction temperature / ℃ standard EMF value/μV Precision grade General grade
Tolerance μV Thermal EMF range μV Tolerance μV Thermal EMF range μV
SorR SC or RC G 100 646 ±30 616~676 ±60 586~706
H 100 646 - - ±60 586~706
200 1 1441 - - 1.381~1 501
         
K KX,KCA G -25 -968 ±40 -924~-1 012 ±80 -880~-1 056
or KCB 100 4 096 4 052~4 140 4 008~4 184
  H -25 -968 ±40 -924~-1 012 ±88 -880~-1 056
100 4 096 4 052~4 140 4 008~4 184
200 8 138 8 094~8 182 8 050~8 226
N NX or NC G -25 -646 ±43 -603~-689 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
H -25 -646 ±43 -603~-690 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
200 5 913 5 870~5 956 5 827~5 999
E EX G -25 -1 432 ±81 -1 351~-1 513 ±138 -1 294~-1 570
100 6 319 6 238~ 6400 6 181~6 457
H -25 -1 432 ±81 -1 351~- 1513 ±138 -1 294~-1 570
100 6 319 6 238~6 400 6 181~6 457
200 13 421 13 340~13 502 13 283~13 559
J JX G -25 -1 239 ±62 -1 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
H -25 -1 239 ±62 - 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
200 10 779 10 717~10 841 10 656~10 902
T TX G -25 -940 ±30 -910~-970 ±60 -850~-1 000
100 4 279 4 249~4 309 4 189~4 339
H -25 -940 ±48 -892~-988 ±90 -850~-1 030
100 4 279 4231~4 327 4 189~4 369
200      


 

Strand Or Solid K Type Thermocouple Extension Wire/Compensation Wire With PFA Insulated PFA Sheath 0 Strand Or Solid K Type Thermocouple Extension Wire/Compensation Wire With PFA Insulated PFA Sheath 1